1 Ton Gas Steam industrial boilers Prices are the problems that customers often consider when purchasing small-tonnage boilers. When we purchase, we must consider the initial investment and the post-operation cost. One-sided.
In addition, share some common knowledge about 1 Ton Gas Steam industrial boilers.
The main components of gas-fired steam boilers include furnaces, economizers, drums, water walls, combustion equipment, air preheaters, furnace walls and structures. Among them, the function of the furnace is to ensure the burning of the boiler gas; the economizer can continue to use the heat of the tail flue gas to save the consumption of gas; the drum is the main body of the boiler, which can store the soda water; the water wall absorbs the radiant heat of the furnace The combustion equipment inputs the gas and the air required for combustion into the furnace; the function of the air preheater is to heat the combustion air and improve the efficiency of the boiler; the furnace wall is the outer shell of the boiler, which can function as a heat preservation and sealing; A bracket that supports the entire boiler.
In addition to these main components, the gas-fired steam boiler includes a drafting device that removes combustion fumes, a dust removing device that removes fly ash, a fuel supply device that stores and transports gas, a water supply device that delivers water to the boiler, a dust removal device, and a delivery device. Wind equipment and automatic control equipment, etc.
When using a gas steam boiler, first ensure that the water used in the boiler is properly treated. Whether it is contaminated water, or water with too high hardness and acidity, it will affect the service life of the boiler, which may cause accidents. Therefore, the heated water must be pretreated when it is input into the steam boiler. The temperature of the input water should be kept above 20 °C and as close as possible to the temperature of the furnace. This is beneficial to improve boiler efficiency and save energy consumption. This is also a good operation for 1 Ton Gas Steam industrial boilers running Prices.
Gas-fired steam boilers must also be regularly maintained and cleaned. The water level gauge must be cleaned once a day. The low-water cut-off device and the water level controller should be cleaned at least once a month. The sewage treatment is carried out once a day. After the treatment, it is necessary to check whether the leakage occurs due to the sewage disposal. If it occurs, it must be repaired in time. Regularly open the front and rear door covers to remove the ash from the pipe to ensure the combustion efficiency of the boiler. The boiler should be maintained after the boiler is shut down. If it is a short-term shutdown, the wet maintenance method can be used, that is, the boiler is filled with water to discharge the air in the furnace. If the furnace is shut down for a long time, it is necessary to drain all the water in the furnace and open the water in the hand-controlled drying furnace. After the moisture is removed, the desiccant is placed in the furnace, and the desiccant needs to be periodically replaced to ensure the drying effect, and it is necessary to take out the desiccant before using the steam boiler again.